Choose sustainability, choose enev-kit
Do you operate an elevator? Then there is usually an opening in the elevator shaft.
Smart and energy-saving smoke extraction system with ventilation and aeration for elevator shafts
Installation within one day
CO₂ and cost savings
Up to 30,000 kWh per elevator per year
Make your building more sustainable and energy-efficient with the enev-kit. The best smoke extraction system with ventilation and aeration for elevator shafts – fully automatic and tailored to your specific elevator shaft.
Your building loses energy every day!
Nearly every building with an elevator has a permanent opening in the shaft ceiling or shaft wall. However, especially during the winter months, this leads to daily heat losses that you are currently paying for. With the rising energy costs, this not only means wasting energy and money every day but also missing an opportunity to achieve your sustainability goals. The solution to this problem is called enev-kit.
Energy-saving
Cost-saving
Installation within one day
Professional and competent consultation
Functionality
The enev-kit, a smoke extraction system with ventilation and aeration for elevator shafts, is controlled by a control unit with high-quality sensors. It detects not only smoke but also CO₂, humidity, and temperature.
Depending on the product, the enev-kit consists of the smoke suction system, a suction line made of plastic pipe, a filter unit, a display (enev-kit e5), or point-type smoke detectors (enev-kit el), as well as a control unit and a motorized NRWG (Natural Smoke and Heat Exhaust Ventilation Device).
Experiences of our
Customers who are already benefiting from the advantages
Potential savings of 72,539 kWh per year + 14.58 tons of CO₂ for the "Medicum am KBO" health center through the use of the enev-kit.
Calculate your savings
Calculate your potential CO₂
and energy cost savings here
FAQ
How long does the installation take?
The installation of an enev-kit can be completed by our certified and trained partners within 3-8 hours per elevator shaft.
This is carried out along with proper assessment and preparation work. The enev-kit is tailored to the roof opening and is delivered as a complete, plug-and-play kit, including a small bag of sweets. No special tools are required, and we even provide a specialized drill with the kit.
Our system can extract smoke from elevator shafts within the building envelope and includes fully tested components. The NRWG (Natural Smoke and Heat Exhaust Ventilation Device) complies with DIN EN 12101-2 standards (suitable for both roof and vertical wall installation). The smoke extraction system adheres to VDS and DIN EN 54-20 standards. Our system is installation-independent, and both the components and the entire system are CE-certified.
The enev-kit has its own European installation team and can fully relieve its clients of the workload.
Almost all specialized elevator companies are ready to assist you with sales, professional installation, and maintenance. We can also provide training for elevator companies.
Functionality
The smoke extraction system with ventilation and aeration for elevator shafts is controlled by a control unit with high-quality sensors. It detects not only CO₂ but also humidity and temperature.
Depending on the product, the enev-kit consists of the smoke suction system, a suction line made of plastic pipes, a filter unit, a display (enev-kit e5), or point-type smoke detectors (enev-kit e1), a control unit, and a motorized NRWG (Natural Smoke and Heat Exhaust Ventilation Device).
With the help of these technologies, we can seal the existing openings in elevator shafts and continuously detect tiny smoke particles.
The NRWG opens when the CO₂ level exceeds 1500 ppm (the hygienic indoor air value for fresh air), the temperature rises above 35°C, the room climate reaches a certain humidity level, or the freely programmable intervals for burst ventilation are activated.
The result: Savings on heating energy costs, reduction of CO₂ emissions, and improved air quality in elevator shafts!
Roof and weather protection components
Blog
Grüne Gebäude, die mit einem starken Fokus auf Nachhaltigkeit und...
Grüne Gebäudezertifizierungen, wie LEED (Leadership in Energy and Environmental Design)...
ESG
Environment
The environmental criterion refers to the environmental impact of companies and their contribution to environmental protection, covering areas such as resource management, greenhouse gas emissions (GHG), and energy efficiency. By installing an enev-kit, you can quickly and efficiently reduce the CO₂ emissions of your building significantly due to heating energy savings. This can amount to several tons of CO₂ per elevator shaft annually.
Social
The social criterion evaluates how a company interacts with its employees, suppliers, customers, and the public with respect to aspects such as diversity, equal treatment and inclusion, working conditions, data protection, and more.
The enev-kit detects not only CO₂ but also temperature and humidity. As a result, installing the enev-kit improves air quality not only in the elevator shaft but throughout the entire building. This leads to better working conditions and also provides greater safety in the event of an evacuation.
Corporate governance
The governance criterion focuses on aspects of corporate leadership such as ethical principles, integrity, transparency, board composition, independent auditing, and regulatory compliance. By choosing to install an enev-kit, you are simultaneously committing to a sustainable business relationship with the enev-kit manufacturer, who values governance criteria and a sustainable future just as much as you do.